Inspect wiring throughout the distribution box and structure. Report on any unsafe wiring such as bare wires that are not terminated in a junction box properly, are close to a metal object, or are hanging where someone could come in contact with it. Inspect main distribution box and note any “Double Tap” circuits where two circuits are improperly wired to one breaker. Observe amperage of breaker and note improperly sized wires feeding circuits or devices. These issues are most commonly found in electrical boxes where it is obvious the homeowner has done the wiring or older homes that have unsafe wiring.